756 N. Pastoria Avenue
Sunnyvale, CA 94085 USA
Phone:408.830.9200
|    
General
Instructions
for Film Storage and Use:
IMPORTANT
DOCUMENT - FORWARD TO PRODUCTION LEAD!
FROZEN
STORAGE – Unless otherwise stated
This adhesive must be stored at (minus) –40°C (°F) or colder at
all times. Storing this adhesive at temperatures warmer than (minus)
–40°C (°F) may alter the adhesives’ properties and shorten its
work life.
DO NOT RE-FREEZE adhesive that has already been thawed!
THAWING PROCESS
Adhesive must reach room temperature before use. Remove syringes
from freezer. Place syringes on end for thawing. See chart below
for thaw time based on syringe size.
| SYRINGE
SIZE |
THAW
TIME |
| 1cc |
5
minutes |
| 3cc |
10
minutes |
| 5cc |
15
minutes |
| 10cc |
20
minutes |
**
NOTE:
To accelerate thaw time, place syringes in front of an air blower
or fan. This will reduce the thaw time by approximately 50%. Remove
all condensation from syringes prior to use.
SURFACE
PREPARATION
Make sure that all surface areas to be bonded are free of any
contamination. If parts have been solvent cleaned make sure solvent
is dried before applying adhesive
APPLICATION
Check the work life of the adhesive, on the technical data sheet.
Adhesives must be used within the work life time period. The adhesives’
properties will change (usually thicken) if it is used past the
allowable work life.
Apply adhesive using dispensing equipment of choice. Contact
Bondline Technical Service with questions about dispensing
adhesives.
CURE
Choose a Cure Option (time & temperature) from the Bondline technical
data sheet. Preheat the oven to the temperature of the selected
cure option. For optimum cure, do not deviate from the selected
cure option. Be sure to allow additional time for holding fixtures
to reach cure temperature. Avoid opening oven doors during cure.
Large fixtures and/or multiple fixtures may require extended cure
time.
SAFETY
Review the adhesive Material Safety
Data Sheet (MSDS) before using. Refer to the MSDS in case
of emergency. Always wear protective gloves and goggles while
handling adhesives. Only work with adhesives in well-ventilated
areas, with curing ovens vented outside. For industrial use only.
TECHNICAL
SERVICE CONTACT
For recommendations and help with any aspect of adhesive applications
please contact the Bondline Technical Service Department (408)
830-9200, or via email: info@bondline.net
|
| |
| |
|